ES
  • English
  • Čeština
  • Deutsch
  • Polski
  • Français
Iniciar sesión

Modular bed error #17256 (XL)

Menu
Relevante para :
Ultima actualización 4 months ago
Este artículo está también disponible en los siguientes idiomas: 
ENCSPLDEFR

What happened? 

If your Original Prusa XL fails to heat correctly one of the heatbed tiles, the printer will show the message "Heatbed tile no. #: Preheat error". 

Error name: MB heater disconnected

Error code: #17256

The error message includes the number of the affected heatbed tile. The error might indicate an issue with the cable connecting the indicated heatbed tile with the modular bed electronics, or with the heatbed tile itself. 

How to fix it? 

A visual inspection

Check that the indicated heatbed cable is correctly connected with the modular bed electronics, and with the heatbed tile, and reseat the connection. 

Check the heatbed tile for physical damage, for example, a scratch on any heatbed tile surface, or a cable in bad status on the bottom of a heatbed tile. 

Swap the cables

Swap the heatbed tile connection indicated on the error with another heatbed tile connector, and check if the indicated heatbed tile number in the error changes, or remains the same after the swap. 

If the error changes to another heatbed tile number after the cables swap, then the cable is causing the error. 

If the error is still the same as before, with the same error code, and on the same heatbed tile number after the swap, most likely the heatbed tile is causing the error. 

If your findings are different than these two cases, or in case of any doubts, do not hesitate to contact our customer support.

¿Fue útil este artículo?

Comentarios

¿Todavía tienes preguntas?

¿Todavía tienes preguntas?

Si tienes alguna pregunta sobre algo que no se ha tratado aquí, comprueba nuestros recursos adicionales.
Y si eso no lo soluciona, puedes enviar una petición a [email protected] o mediante el botón que hay más abajo.