How to replace a Lid safety switch (CW1)

How to replace a Lid safety switch (CW1)

How to replace a Lid safety switch (CW1)
Relevant for:
Last updated 3 years ago
How to replace a Lid safety switch (CW1)
 Difficulty
Moderate
 Steps
21
 Available languages
CSPLDEESITFR
Introduction
Introduction
This guide will take you through the replacement of the Lid safety switch on the Original Prusa CW1.
All necessary parts are available in our shop shop.prusa3d.com
Note that you have to be logged in to have access to the spare parts section.
WARNING: This device utilizes UV light, which can harm your eyesight or skin. Do not turn the device ON until it is fully reassembled with all the covers installed!!!
Removing the lid
Removing the lid
Removing the lid
Open the lid, all the way to the back.
Remove gastro pan from the CW1.
Release four screws on both hinges.
Carefully remove the lid with hinges.
Manipulate with the lid carefully, it can be easily scratched.
Removing the top cover
Removing the top cover
Removing the top cover
Removing the top cover
Proceed carefully with these screws, preferably use an Allen key with straight sharp edges, there is a risk of stripping the screw's head.
Turn the left side of the CW1 towards you.
Locate, release, and remove three screws.
Turn the CW1 to the other side (180 °) and again remove three screws.
Remove the front cover from the CW1.
Removing the rear cover
Removing the rear cover
Removing the rear cover
Removing the rear cover
Proceed carefully with these screws, preferably use an Allen key with straight sharp edges, there is a risk of stripping the screw's head.
Turn the left side of the CW1 towards you.
Release and remove two screws on the side.
Turn the right side of the CW1 towards you.
Release and remove two screws on the side.
Release and remove two screws on the top of the rear cover.
Removing the top cover
Removing the top cover
Removing the top cover
Removing the top cover
Be extra careful!!! The steel parts on the machine have sharp edges. Avoid cutting yourself!
Release and remove four screws on the top cover.
Carefully grab both gastro pan holders and slightly push them down and out. The stainless steel sheet bends slightly - that's alright.
As soon as the steel sheet with the holders pops out, grab one holder with your hand and use the other hand to grab the sheet near the rotating the platform. Then carefully remove this assembly out. Be careful, there are cables attached to it!!!
Removing the top cover
Removing the top cover
Removing the top cover
Be extra careful!!! The steel parts on the machine have sharp edges. Avoid cutting yourself!
Carefully remove the top part from the machine and put it next to the CW1 so that the filtration fan is facing you, like in the picture. Do not pull the cables!!!
Cut the zip tie on the cables from the covercheck assembly, LEDs and IR-sensor. Be careful, avoid cutting cables!!!
Disconnecting the covercheck assembly
Disconnecting the covercheck assembly
Disconnecting the covercheck assembly
Disconnect the lid safety switch (red & black) cable from the Prusa CW-Controller.
Disconnect the thermistor (red & black) cable from the Prusa CW-Controller.
Removing the lid safety switch
Removing the lid safety switch
Removing the lid safety switch
Locate the lid safety switch on the inside of the top cover.
Release the screw on the lid safety switch.
Remove the lid safety switch from the top cover.
Removing the lid safety switch
Removing the lid safety switch
Removing the lid safety switch
Remove the covercheck-bottom part from the covercheck-top.
Remove the lid safety switch.
Keep the printed parts and the thermistor for the upcoming steps.
Lid safety switch installation
Lid safety switch installation
Lid safety switch installation
Insert the lid safety switch in the covercheck-top part from the same side as the thermistor. In other words, both sensors will have cables on the same side of the printed part.
Make sure that the thermistor did not fall out of the covercheck-top.
Finish the assembly using the covercheck-bottom part. Ensure no wire is pinched or bent!!!
Mounting the covercheck assembly
Mounting the covercheck assembly
Mounting the covercheck assembly
To properly mount the covercheck assembly to the top cover, follow these instructions:
The circular hole in the printed parts must fit on the "extension" nut welded to the sheet.
The button of the switch has to go through the hole.
Align the assembly with the edge of the cover.
Secure the covercheck assembly using the M3x5 screw.
Connecting the covercheck cables
Connecting the covercheck cables
Connecting the covercheck cables
Connecting the covercheck cables
Connect the thermistor cable to the Prusa CW-Controller.
Connect the lid safety switch cable to the Prusa CW-Controller.
Put the lid safety switch, thermistor, LED power cable and IR-sensor cables together and secure them with the zip tie. Do not overtighten the zip tie! You may damage the cables.
Mounting the top cover
Mounting the top cover
Mounting the top cover
Mounting the top cover
Be extra careful!!! The steel parts on the machine have sharp edges. Avoid cutting yourself!
Put the cover back in the CW1.
Squeeze the edges of the cover slightly to get under the rear cover.
Make sure no cables are pinched under the cover and make sure the cables do not interfere with the lower fan.
Mounting the rear cover
Mounting the rear cover
Mounting the rear cover
Align both screw holes on the top of the rear cover with the holes in the stainless steel cover.
Insert two M3x5b countersunk screws into the holes and tighten it.
Mounting the rear cover
Mounting the rear cover
Mounting the rear cover
Turn the left side of the CW1 towards you.
Secure the rear cover with two M3x5b countersunk screws.
Turn the right side of the CW1 towards you.
Secure the rear cover with two M3x5b countersunk screws.
Mounting the front cover
Mounting the front cover
Mounting the front cover
Mounting the front cover
Carefully place the front cover on the CW1.
Turn the left side of the CW1 towards you.
Secure the cover with three M3x5b countersunk screws.
Turn the right side of the CW1 towards you.
Secure the cover with three M3x5b countersunk screws.
Securing the top cover
Securing the top cover
Securing the top cover
Securing the top cover
Align all four holes in both parts.
Secure the top cover with four M4x8b countersunk screws.
Mounting the lid
Mounting the lid
Mounting the lid
Mounting the lid
Mount the lid with hinges back to the CW1 and slightly tighten the screws.
Adjust the screws in the oval holes to the same position on both hinges. Tighten the screws.
Close the lid and check on the sides that it fits correctly on the rear cover along its entire length. If necessary, adjust the position of the hinges.
It’s done!
It’s done!
Great job! You've just changed the lid safety switch on the CW1 machine.