The printer is showing the message "Hotend thermal runaway: Check the print head thermistor wiring for possible damage."
Error name: Hotend thermal runaway
Error code: #23204
The error will show if the temperature on the nozzle drops by 12 ºC for an extended period of time. This temperature drop would usually not be an issue, but if the heat is not recovered after 60 seconds the error will happen. In this case, the printer will stop the heating and display the message on the screen.
If the issue persists, the error likely stemmed from an issue with the hotend heater or hotend thermistor. To find out which one of these two is malfunctioning, perform the test described below.
Use a hairdryer to blow hot air towards the hotend. In the meantime, check if there is any temperature change on the LCD screen.
If you have a question about something that isn't covered here, check out our additional resources.